Product name: Thermocouple Bares Wire Size: Customized Size Application:Temperature Sensors, temperature inspector Conductor Type:Solid Insulation Material:None Temperature range: 0~1700°C EMF Tolerance:+/- 2.2C Or +/- .75% Positive:Platinum Rhodium-30%  Negative:Platinum Rhodium-6% Special Limits Of Error:+/- 0.25%



WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
img of mask_layer_close
Type B Platinum Rhodium Thermocouple Bare Wire
Type B Platinum Rhodium Thermocouple Bare Wire
Type B Platinum Rhodium Thermocouple Bare Wire
Type B Platinum Rhodium Thermocouple Bare Wire
Type B Platinum Rhodium Thermocouple Bare Wire
Product Detail

Products Description

Type B Platinum Rhodium Thermocouple Bare Wire is a thermocouple bare wire designed specifically for high-precision temperature measurement. It is made of platinum rhodium alloy, ensuring stability and reliability within extreme temperature ranges. B-type platinum rhodium thermocouple bare wire is a commonly used temperature sensor element, composed of platinum and rhodium. This model of thermocouple bare wire has excellent high-temperature measurement performance and can provide reliable temperature measurement in the range of 0 ° C to 1800 ° C. Its characteristics include high sensitivity, good linear characteristics, and stability, suitable for various industrial fields such as refining, chemical industry, metallurgy, heat treatment, etc. B-type platinum rhodium thermocouple bare wire is widely used in the field of temperature monitoring, control, and recording, providing an important temperature measurement solution for industrial production.


Parameter

ASTM

(American Society for Testing and Materials) E 230

ANSI

(American National Standard Institute) MC 96.1

IEC

(European Standard by the International Electrotechnical Commission 584)-1/2/3

DIN

(Deutsche Industrie Normen) EN 60584-1/2

BS

(British Standards) 4937.1041, EN 60584-1/2

NF

(Norme Francaise) EN 60584-1/2-NFC 42323-NFC 42324

JIS

(Japanese Industrial Standards) C 1602-C 1610

GOST

(Unification of the Russian Specifications) 3044


Code

+Positive leg

-Negative leg

Temperature Range

N

Ni-Cr-Si (NP)

Ni-Si-Mg (NN)

-454 to 2300°F (-270 to 1,260°C)

K

Ni-Cr-Si (KP)

Ni-Al (KN)

–454 to 2,300°F (–270 to 1260°C)

E

Ni-Cr (EP)

Cu-Ni<constantan> (EN)

-454 to 1600°F (-270 to 870°C)

J

Iron (JP)

Cu-Ni<constantan> (JN)

-346 to 1,400°F (-210 to 760°C)

T

Copper (TP)

Cu-Ni<constantan> (TN)

-454 to 700°F (-270 to 370°C)

B

Platinum Rhodium-30%

Platinum Rhodium-6%

32 to 3100°F (0 to 1700°C)

R

Platinum Rhodium-13%

Platinum

-58 to 2700°F (-50 to 1480°C)

S

Platinum Rhodium-10%

Platinum

-58 to 2700°F (-50 to 1480°C)

C (W-Re5/26)

Tungsten 5% Rhenium

Tungsten 26% Rhenium

212 to 4172°F (100 to 2300°C)

D (W-Re3/25)

Tungsten 3% Rhenium

Tungsten 25% Rhenium

212 to 4172°F (100 to 2300°C)

G (W-Re26)

Pure Tungsten

Tungsten 26% Rhenium

212 to 4172°F (100 to 2300°C)


For more details, pls directly contact us.


Main features:

High precision measurement: Type B thermocouple bare wires can provide extremely accurate temperature readings, suitable for industrial process control that requires high accuracy.

Wide temperature range: It can operate within a wide temperature range of -200 ° C to+1700 ° C, meeting various industrial application requirements.

Corrosion resistance: The chemical stability of platinum rhodium alloy gives it excellent corrosion resistance, making it suitable for use in harsh environments.

Long lifespan: High quality materials and manufacturing processes ensure the long lifespan and durability of Type B thermocouple bare wires.

Easy to install: The bare wire form makes installation and maintenance easier, suitable for various complex industrial environments.


Application field:

Chemical industry: used to monitor the temperature of chemical reactors, distillation towers, and other high-temperature equipment.

Metal processing: Monitoring temperature during forging, casting, and heat treatment processes.

Power industry: used to monitor the temperature of boilers and steam pipelines in power plants.

Aerospace: Testing and monitoring the temperature of aircraft components under extreme temperature conditions.

Food processing: Ensure that temperature control during food processing meets safety standards.


Why choose Type B Platinum Rhodium Thermocouple Bare Wire?

Our products adopt the most advanced manufacturing technology, ensuring excellent performance and quality.

We provide customized services to meet your specific application needs.

Our customer service team is always ready to assist you in resolving any technical issues.


Contact us:

Contact us immediately to learn more about Type B Platinum Rhodium Thermocouple Bare Wire, or to obtain a quote for a customized solution.


Related products
Inquire Now
Name: *
Mobile:
E-mail: *
Message: *
Related products
Other products
Hot products

    COMPANY PROFILE

    Jiangsu Dzx Technology is a company dedicated to the production and research and development of alloys. Founded in 2002, we initially focused on the production of resistance alloys.

      CONTACT US

      E-mail: dzx@dlx-alloy.com

      Mobile: +8619906119641

      Tel: 0086-19906119641

      WhatsApp: +86-19906119641

      Add: NO.32 West Taihu Road, Xinbei District, Changzhou, Jiangsu

    CopyRight © 2026 Jiangsu Dzx Technology Co., Ltd. All rights reserved Sitemap  All tags 
    Company Name
    *
    This field is required
    Email
    *
    This field is required
    Email format error
    Phone
    This field is required
    Telephone information is wrong!
    Message
    *
    This field is required
    Send Message